Knob-and-Tube Wiring

How it became the Romex in your walls today, and the specific conditions that make it dangerous.

If your King County home was built before about 1950, there's a real chance some knob-and-tube wiring is still in the walls, attic, or basement. It was the original wiring of the American home, and its reputation is part earned and part myth. Knob-and-tube isn't automatically a hazard. Specific conditions turn it into one, and you can identify them. The sections below cover how it works and how modern cable grew out of it, then describe the conditions that make it a concern.

What knob-and-tube is

Knob-and-tube wiring (often shortened to "K&T") was the dominant method for wiring buildings in North America from roughly the 1880s through the 1930s, lingering into the 1940s and later in some areas. The name comes from its two signature ceramic parts:

  • Knobs are ceramic spools nailed to the framing. The wire is tied off to them so it runs suspended in open air, held a safe distance away from the wood.
  • Tubes are ceramic sleeves inserted into holes drilled through joists and studs, so a wire passing through framing never touches the wood directly.

The two conductors (the "hot" and the "neutral") also run as separate single wires spaced several inches apart instead of bundled together in one cable. There is no third wire. Knob-and-tube has no equipment grounding conductor at all, which is why the outlets it feeds are the old two-prong kind.

Ungrounded two-prong wall outlet in a freshly finished room with new flooring and trim, a sign of old ungrounded wiring behind the walls

A two-prong outlet with no ground slot is the most visible clue. A room can be freshly painted, floored, and trimmed and still be running on old ungrounded wiring behind the walls

Original knob-and-tube wiring in an attic, with conductors suspended from ceramic knobs and running through the framing in open air

Original knob-and-tube in a King County attic: the ceramic knobs hold each conductor up in open air, spaced away from the framing, exactly as it was designed to be run

Why it was good engineering, for its time

Bare-looking wires strung through an attic can look primitive, but the open-air spacing was deliberate. Air sheds heat well, and keeping the two wires apart reduced the chance of a fault between them. For a 1915 home's load (a few lights, maybe a radio) it was a sound, code-compliant system. Most of the problems blamed on knob-and-tube today come from age and from what later owners did to it, including loading it far past anything it was designed for.

How wiring evolved from knob-and-tube to Romex

Knob-and-tube wasn't banned overnight. Cable systems replaced it gradually because they were faster to install and safer to conceal, and eventually they carried a ground. The rough timeline:

  • Knob-and-tube (1880s–1930s): separate conductors, ceramic supports, no ground, insulation made of rubber and cloth.
  • Armored cable, "BX" (early 1900s onward): conductors bundled inside a flexible spiral metal sheath. This put both wires in one protected run and offered a degree of physical protection knob-and-tube didn't.
  • Early nonmetallic cable, the first "Romex" (1920s): the Romex brand name dates to around 1922. Early nonmetallic-sheathed (NM) cable bundled the conductors inside a fabric-and-tar jacket, but still had no dedicated ground wire.
  • Grounded NM cable (roughly the 1960s): as the code began requiring equipment grounding on branch circuits, NM cable gained a third conductor, the bare or green equipment ground. This is the era that gave us three-prong outlets as standard.
  • Modern NM-B (1980s to today): today's Romex is "NM-B," with heat-resistant insulation rated to a higher temperature and a grounding conductor throughout. It's what a new circuit in your home is wired with now.

The "Romex" in a modern wall and the knob-and-tube in an old one do the same basic job. A century of changes separates them, and the safety margins are very different.

When knob-and-tube is dangerous

It isn't dangerous in every case. Functional, undisturbed knob-and-tube in good condition can operate safely. The danger comes from specific conditions, and most of them trace back to what happened to the wiring over the last several decades, not to the original installation.

⚠️ The conditions that make K&T a real hazard

  • Buried in thermal insulation. This is the most serious condition. Knob-and-tube was designed to shed its heat into open air. When someone later blows or packs insulation into an attic or wall cavity around it, that heat has nowhere to go and the conductors can run hot. It's a common, well-documented problem in energy retrofits, and the electrical code (NEC Article 394) specifically prohibits knob-and-tube inside insulation-filled spaces for this reason.
  • Degraded or missing insulation. The original rubber-and-cloth insulation becomes brittle after 70-plus years. It cracks and flakes off, especially near heat and at connection points, until bare energized copper is exposed.
  • No ground. With no equipment grounding conductor, the system can't safely serve modern grounded appliances or electronics, and it offers less protection in a fault. Those three-to-two-prong "cheater" adapters don't add a ground; they only conceal that it's missing.
  • Amateur modifications and bad splices. Original K&T splices were soldered and taped by hand. Decades of DIY add-ons are a frequent source of loose, overheating connections: taps spliced in with wire nuts buried in a wall, extensions, modern cable mixed in.
  • Overloading. A system sized for 1920s lighting is now often asked to run space heaters and window AC units, plus power strips full of electronics. That's far beyond what it was built to carry.
Close-up of an old cloth-insulated cable with brittle insulation cracked open, exposing the conductor underneath

Decades of heat and age on cloth-and-rubber insulation. This particular piece is an old range/oven cable, not knob-and-tube, but K&T's insulation fails exactly the same way: it goes brittle, cracks, and splits open until energized copper is exposed.

Nearly every serious knob-and-tube hazard is a condition you can inspect for. So a real evaluation is worth more than a blanket "it's old, rip it all out." Sometimes full replacement is the right call. Other times a targeted fix is the safe move. It depends on what's back there.

Old cloth-covered knob-and-tube conductor spliced to modern white NM-B Romex cable with wire connectors near a recessed light in an attic

A common find: old knob-and-tube (the black cloth-covered conductor) tied into modern NM-B Romex with wire connectors, the kind of later modification that's often where trouble starts

The insurance angle

Knob-and-tube that is operating safely can still cause an insurance problem. Many carriers won't write a new policy on a home with active knob-and-tube, or will charge a premium for it. This usually comes up in the middle of buying or selling an older home, when there's little time to deal with it. If you're planning to buy an older King County house, find out what's in the walls before the appraisal, not during it.

What to do if you think you have it

The two-prong outlets, the ceramic knobs visible in the attic or basement, and the separate cloth-covered wires are the usual giveaways. If you spot them, get an assessment: how much is still in service, what condition the insulation is in, whether it's buried under insulation, and how much has been modified over the years. From there the options range from leaving sound sections alone to replacing runs to a full rewire. A licensed electrician can tell you which one your house needs. Knob-and-tube also tends to turn up alongside the aging panels and fuse boxes of the same era, so it's often worth looking at the whole system at once.

Washington's current code

Washington State currently enforces the 2023 NEC, in effect since April 2024. Concealed knob-and-tube wiring is covered under NEC Article 394, and the unamended national rule (394.12) prohibits it in spaces filled with thermal insulation. Washington amends that rule.

WAC 296-46B-394 states that Article 394 does not prohibit loose or rolled thermal insulating material in spaces containing existing knob-and-tube wiring, provided all three of the following are met:

  • The wiring is surveyed by an appropriately licensed electrical contractor, who certifies in writing to L&I that it is in good condition, with no improper overcurrent protection, no conductor insulation failure or deterioration, and no improper connections or splices.
  • The insulation meets Class I specifications with a flame spread factor of 25 or less as tested under ASTM E84-81a. Foam insulation may not be used with knob-and-tube.
  • Every knob-and-tube circuit has overcurrent protection per NEC Table 310.16, 60°C column, using circuit breakers or Type S fuses.

In Washington, then, insulating an attic over sound knob-and-tube is a permitted job with an inspection gate in front of it. It is not an automatic violation. A licensed electrical contractor does the survey and the written certification. Energy retrofits often skip that step, and those installations end up non-compliant. New knob-and-tube isn't installed today. That code article exists mainly to govern what's already in older homes.

Sources

  • National Fire Protection Association, NFPA 70: National Electrical Code, Article 394 (Concealed Knob-and-Tube Wiring), including 394.12 (Uses Not Permitted), 2020 and 2023 editions.
  • Washington State Department of Labor & Industries, WAC 296-46B (Electrical Safety Standards), adoption of the 2023 NEC effective April 1, 2024. See L&I's Electrical Laws, Rules & Policies page.

This is general educational information, not a substitute for an in-person evaluation of your specific wiring by a licensed electrician.

You're welcome to quote this article elsewhere with attribution and a link back to the original at hancoelectric.com.